1. Main motor (M3)
The main motor is a DC brushless motor which is controlled by control signals output from the MAIN
board. The driving force of the main motor is transmitted to the drum, developer unit, cleaner unit,
fuser unit and the rollers which transport the paper, via gears and clutch.
2. Toner motor (M2)
The toner motor is a DC brush motor which is controlled by control signals output from the MAIN
board. The driving force of the toner motor is transmitted to the toner cartridge via gears.
Unit to be driven
Drive transmission
Main motor (M3)
Drum
Gears
Developer unit (Mixer)
Gears
Cleaner unit (Toner recovery auger)
Gears
Fuser unit (Fuser roller)
Gears
Rollers (Paper feed roller and Bypass feed roller.)
Gears, clutch
Toner motor (M2)
Toner cartridge
Gears