05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
23LA
23LM/
28LM
23HA/
28HA
08
Setting
mode
Process
Developer
Developer bias
Hi1correction (Text)
2920
3
PPC
128
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
Y
08
Setting
mode
Process
Developer
Developer bias
Hi1correction
(Photo)
2920
4
PPC
128
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
Y
08
Setting
mode
Process
Developer
Developer bias
Hi1correction
(Normal)
GDI
2920
5
PRT
128
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
Y
08
Setting
mode
Process
Developer
Developer bias
Hi1correction
2920
6
FAX
128
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
-
-
Y
08
Setting
mode
Process
Developer
Developer bias
Hi1correction
(Normal / OHP film)
PCL
2921
0
PRT
108
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
-
-
Y
08
Setting
mode
Process
Developer
Developer bias
Hi1correction (Toner
saving mode / OHP
film)
2921
1
PRT
108
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
Y
08
Setting
mode
Process
Developer
Developer bias
Hi1correction
(Normal / OHP film)
2921
2
PPC
108
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
Y
08
Setting
mode
Process
Developer
Developer bias
Hi1correction (Text /
OHP film)
2921
3
PPC
108
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
Y
08
Setting
mode
Process
Developer
Developer bias
Hi1correction (Photo
/ OHP film)
2921
4
PPC
108
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
Y
08
Setting
mode
Process
Developer
Developer bias
Hi1correction
(Normal / OHP film)
GDI
2921
5
PRT
108
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
Y
08
Setting
mode
Process
Developer
2922
-
Developer bias
Hi2correction
123
0-255
M
Compensation value: GAP from 128 is given to an
execution value
1
Y
Y
Y
08
Setting
mode
Process
Charger
Main charger bias
correction (Normal)
PCL
2926
0
PRT
128
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
Y
08
Setting
mode
Process
Charger
Main charger bias
correction (Normal /
Toner saving mode)
2926
1
PRT
128
0-255
M
Compensation value: GAP from 128 is given to an
execution value
4
Y
Y
Y
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
14-2-39
e-STUDIO2303A/2303AM/2803AM/2309A/2809A
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)