e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 58
[C4B0] Fixer error counter outside of specification
Classification
Error content
Fuser unit related service call
Fixer error counter outside of specification
Check item
Measure
1. Check the MAIN board
1. Check if the conductor pattern on the MAIN board is short
circuited or open circuited.
2. Check if the memory
*
is installed properly.
* 23LA/23LM/28LM: IC10
20L/23L/25L/20H/23H/25H,23HA/28HA: IC11
3. Replace the MAIN board
2. Clear the status counter
After repairing the matter which caused the error [C4B0],
perform the following:
1. Turn ON the power while [0] and [8] are pressed
simultaneously.
2. Key in “2002”, then press [START].
3. Rewrite the displayed counter with “0” and then press the
[OK] button ([C4B0] clear).
4. Turn the power OFF and then back ON. Make sure that the
equipment enters the normal ready state.
Parts to be replaced
Remark
MAIN board