HYDRAULIC TESTING
9-10
Rev. 000
TX525 Service Manual
Flow Gauge Removal
1. Let the engine and hydraulic oil cool prior to loosen-
ing any hydraulic fittings.
2. Cycle the loader valve handle to relieve any pres-
sure in the system.
3. Place an oil drain pan under the flow meter hydraulic
connections.
4. Disconnect the hydraulic pump hose from the
adaptor fitting using a 7/8” wrench on the adaptor
fitting and a 15/16” wrench on the pump hose (Fig.
1858).
Fig 1858
PICT-3406
5. Using a 1516” wrench on the hose and a 7/8”
wrench on the adaptor, remove the adaptor from the
flow meter hose (Fig. 1859).
Fig 1859
PICT-3405
6. Using a 15/16” wrench, disconnect the flow meter
hose from the hydraulic pump (Fig. 1860).
Fig 1860
PICT-3404