SECTION 7
7-26
1-/ 2-Cylinder
6. Disconnect CD Unit
(8)
terminals
(5)
and
(6)
.
7. Connect one meter lead to terminal
(6)
and the other to
terminal
(2)
and check continuity. If the meter does not show
continuity, replace the cable.
8. Connect one meter lead to terminal
(6)
and the other to a
clean engine ground. If the meter shows continuity, replace
the cable.
9. Reconnect aIl wires and return to Test 2 - Stop Circuit Test flow
chart.
Test 2b - Stop Circuit Emergency Stop Switch Test
This test is used to determine whether the emergency stop switch
and connecting wiring are functioning normally.
NOTIE
Make sure aIl electrical terminals are connected
during this test except those that are noted in the
test pro cedure.
Check for continuity between chassis ground and
the ground connection for the magneto plate, CD
Unit, and ignition coils before conducting the
following procedure.
All continuity tests must be conducted with negative
lead from battery disconnected or you may damage
the meter.
5
5
5
T1476
5
Summary of Contents for 2 Stroke Cylinder Series
Page 1: ...PNo 003 21035 1 0509 NB 1000 Printrd in Japan 1 05 8 23 1 33 PM 1...
Page 99: ...SECTION 4 4 18 1 2 Cylinder T2201 16...
Page 103: ...POWERHEAD 4 23 1 2 Cylinder POWERHEAD Typical 1 Cylinder T1676...
Page 104: ...SECTION 4 4 24 1 2 Cylinder Typical 2 Cylinder T1677...
Page 140: ...SECTION 5 5 22 1 2 Cylinder 8 T1620...
Page 162: ...SECTION 6 6 10 1 2 Cylinder GEARCASE Typical Gearcase 2 5 3 5 T1709...
Page 165: ...GEARCASE 6 13 1 2 Cylinder Typical Gearcase 3 5B T1714...
Page 169: ...GEARCASE 6 17 1 2 Cylinder Typical Gearcase 8 9 8 9 9 15 18 25 30 40 T1723...
Page 214: ...SECTION 7 7 22 1 2 Cylinder Ignition System Performance Testing Flow Chart 1 T1557 1...