SECTION 6
6-32
1-/ 2-Cylinder
10. Mount a magnetic base and dial gauge (obtain locally) as
shown. Lift driveshaft upward and tap down on gearcase
with rubber mallet to eliminate all looseness and proceed to adjust
the setup so dial gauge
(19)
is aligned with V-notch
(20)
.
11. Set dial gauge to zero. Lift driveshaft upward and rotate
driveshaft in both directions and record the dial gauge
reading.
If the dial gauge reading is not within the specified range,
adjust shim thickness between bevel gear A
(21)
and
tapered roIIer bearing
(22)
in accordance with the Backlash - Shim
Adjustment Table, this section. See Gearcase Repair Procedures in
this section for removal and installation of the bevel gearA roller
bearing.
Model
Acceptable Dial Gauge Reading
in
mm
3.5B
0.008 - 0.025
0.21 - 0.62
5
0.006 - 0.019
0.16 - 0.49
8 / 9.8
0.0056 - 0.0165
0.14 - 0.42
9.9 / 15 / 18
0.0147 - 0.0240
0.38 - 0.61
25 / 30
0.0130 - 0.0213
0.33 - 0.54
40
0.0236 - 0.0394
0.60 - 1.00
T1746
40
41
42
T1411
T1747
Summary of Contents for 2 Stroke Cylinder Series
Page 1: ...PNo 003 21035 1 0509 NB 1000 Printrd in Japan 1 05 8 23 1 33 PM 1...
Page 99: ...SECTION 4 4 18 1 2 Cylinder T2201 16...
Page 103: ...POWERHEAD 4 23 1 2 Cylinder POWERHEAD Typical 1 Cylinder T1676...
Page 104: ...SECTION 4 4 24 1 2 Cylinder Typical 2 Cylinder T1677...
Page 140: ...SECTION 5 5 22 1 2 Cylinder 8 T1620...
Page 162: ...SECTION 6 6 10 1 2 Cylinder GEARCASE Typical Gearcase 2 5 3 5 T1709...
Page 165: ...GEARCASE 6 13 1 2 Cylinder Typical Gearcase 3 5B T1714...
Page 169: ...GEARCASE 6 17 1 2 Cylinder Typical Gearcase 8 9 8 9 9 15 18 25 30 40 T1723...
Page 214: ...SECTION 7 7 22 1 2 Cylinder Ignition System Performance Testing Flow Chart 1 T1557 1...