68
Operation Checkout Procedures (continued)
7.
Rotate Mode Selection knob to
Air Conditioning Mode
.
a.
Snowflake icon should flash for several seconds then stay on.
b.
Fan speed LEDs should turn off and AUTO indicator LED should come on. The fan should run in low.
c.
If cab temperature is above 68 F the compressor may start and evaporator fan speed may increase.
8.
Rotate Mode Selection knob to
Heat Mode
.
a.
Heat icon should flash for several seconds then stay on.
b.
Evaporator fan should stop or remain off.
c.
The fan OFF indicator LED should come on.
d.
Depending on cab temperature the heater may start.
Note: If the heater ignites it will run for a minimum of 5 minutes. The blower will then run through a cool down cycle.
9.
Rotate Mode Selection knob back to
Fan Mode
.
a.
Evaporator fan should not run.
b.
Rotating the fan speed knob will start the evaporator fan.
10.
Battery Monitor Display.
a.
Watch battery level display for approximately 30 seconds.
b.
At least four green battery level bars should illuminate steady green.
11.
Press Mode Selection knob for at least three seconds to turn system OFF.
a.
All indicator LEDs should turn off.
b.
Evaporator fan should stop if running.
THIS COMPLETES STEP 1 – VERIFYING BASIC SYSTEM OPERATIONS
DO NOT TURN THE SYSTEM OFF
CONTINUE TO STEP 2 – VERIFYING DETAILED SYSTEM OPERATIONS
Summary of Contents for TriPac Envidia
Page 2: ......
Page 11: ...9 Battery Box Dimensions Figure 1 Battery Box Dimensions...
Page 12: ...10 Battery Box Dimensions continued Figure 2 Battery Box Dimensions continued...
Page 13: ...11 Evaporator Control Box Dimensions Figure 3 Evaporator Control Box Dimensions...
Page 14: ...12 Condenser with Receiver Drier Dimensions Figure 4 Condenser with Receiver Drier Dimensions...
Page 15: ...13 HMI Dimensions Figure 5 HMI Dimensions...
Page 16: ...14 1000 Watt Power Inverter Dimensions Option Figure 6 1000 Watt Power Inverter Dimensions...
Page 18: ...16 D2 D4 Heater Dimensions Option Figure 8 Heater Dimension...
Page 19: ...17 BLANK PAGE...
Page 21: ...19 Typical Component Locations Figure 9 Typical Component Locations...
Page 45: ...43 A C Duct Installation continued FLUSH MOUNTED EVAPORATOR Figure 21 A C Duct locations...
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......