![background image](http://html1.mh-extra.com/html/thermo-king/tripac-envidia/tripac-envidia_installation-manual_1104402039.webp)
37
D2/D4 Heater Installation (Heat Option)
Heater Location
IMPORTANT: Correct installation of this heater is necessary to ensure safe and proper operation.
BEFORE installing the heater, thoroughly read and understand the heater manufacturer’s manual included with
the heater.
The location for mounting the heater will vary depending on the type of tractor. Typically, the heater is mounted inside
the sleeper, under the bunk in a storage compartment. However, the heater may be mounted anywhere inside the tractor
provided you adhere to the following conditions:
•
Install heater so it will maintain a minimum distance of 2.00 inches (50.8 mm) from any heat sensitive or
flammable material.
•
Combustion air intake, exhaust and fuel inlet must be located outside the tractor.
•
Install exhaust hose so it will maintain a minimum distance of 2.00 inches (50.8 mm) from any heat sensitive
or flammable material.
•
Heater must be mounted on flat horizontal surface providing an air tight seal between heater and tractor.
•
All floor matting, carpet, insulation, etc. must be removed to allow the heater to be mounted directly to the
bare floor.
•
Heater harness may be repositioned to either side of the heater.
•
Floors made of fiberglass covered wood construction require the edges of the access hole be sealed with
fiberglass and epoxy resin.
Drilling Hole in Floor
Special Tools Required
Drill Motor
Utility Knife
Center Punch
4-1/4” dia. Hole Saw
Fiberglass Cloth and Resin Kit (if required)
1.
Position the heater’s metal
mounting plate onto the
floor mat.
2.
Use a utility knife to cut the
floor mat around the outside
edges of the plate. Remove
floor mat to access the bare
floor.
3.
With the mounting plate in
position, center punch the
four outer holes. Remove
the mounting plate and
mark an “X” connecting the
four center punched outer
holes.
4.
Center punch the center of
the “X” and drill a 4-1/4”
hole with a hole saw.
Figure 17: Marking and Cutting the Hole.
Summary of Contents for TriPac Envidia
Page 2: ......
Page 11: ...9 Battery Box Dimensions Figure 1 Battery Box Dimensions...
Page 12: ...10 Battery Box Dimensions continued Figure 2 Battery Box Dimensions continued...
Page 13: ...11 Evaporator Control Box Dimensions Figure 3 Evaporator Control Box Dimensions...
Page 14: ...12 Condenser with Receiver Drier Dimensions Figure 4 Condenser with Receiver Drier Dimensions...
Page 15: ...13 HMI Dimensions Figure 5 HMI Dimensions...
Page 16: ...14 1000 Watt Power Inverter Dimensions Option Figure 6 1000 Watt Power Inverter Dimensions...
Page 18: ...16 D2 D4 Heater Dimensions Option Figure 8 Heater Dimension...
Page 19: ...17 BLANK PAGE...
Page 21: ...19 Typical Component Locations Figure 9 Typical Component Locations...
Page 45: ...43 A C Duct Installation continued FLUSH MOUNTED EVAPORATOR Figure 21 A C Duct locations...
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......