34
A/C Hose Installation
Installation
IMPORTANT: Keep all the A/C fittings capped and sealed until the installation of the refrigeration hoses.
Refrigerant oil is extremely hygroscopic and a system left open for more than 5 minutes may require extensive
evacuation/dehydration time to remove moisture.
NOTE: The Evaporator/Control Box system has a Nitrogen holding charge of 5 PSI. This holding charge can safely
be vented into the atmosphere.
NOTE: Read and understand Fabricating Refrigeration Hoses section for proper hose fabrication requirements.
IMPORTANT: Always use two wrenches while tightening refrigeration fittings.
Condenser Coil to Evaporator/Control Box (Discharge Line)
1.
Fabricate a
#6 hose
with a 90 degree fitting and connect to the fitting on the
condenser coil inlet
(top
connection). Tighten the fitting to 15-20 ft-lb (20-27 N•m). Use a backup wrench.
2.
Route the hose up through the 2” access hole in the tractor floor near the Evaporator/Control Box air
conditioning fittings.
3.
Cut the hose to length, install a 90 degree fitting with service port and attach it to the
large
fitting on the
Evaporator/Control Box. Tighten the fitting to 15 to 20 ft-lb (20 to 27 N•m). Use a backup wrench.
Receiver Drier to Evaporator/Control Box (Liquid Line)
4.
Fabricate a
#4 hose
with a 90 degree fitting and attach onto the
receiver liquid line outlet
fitting on the
receiver drier. Tighten the fitting to 11 to 13 ft-lb (15 to 17 N•m). Use a backup wrench.
5.
Route the hose up through the 2” access hole in the tractor floor near the Evaporator/Control Box air
conditioning fittings.
6.
Cut the hose to length, install a 90 degree fitting and attach onto the
small
fitting on the Evaporator/Control
Box. Tighten the fitting to 11 to 13 ft-lb (15 to 17 N•m).
7.
Secure all hoses adequately with clamps or band wraps.
Special Tools Required
Hose Fitting Tool (204-1045)
Hose Cutting Tool (204-677)
Alkyl Benzene refrigerant oil (670404TKA).
Torque Wrench
Summary of Contents for TriPac Envidia
Page 2: ......
Page 11: ...9 Battery Box Dimensions Figure 1 Battery Box Dimensions...
Page 12: ...10 Battery Box Dimensions continued Figure 2 Battery Box Dimensions continued...
Page 13: ...11 Evaporator Control Box Dimensions Figure 3 Evaporator Control Box Dimensions...
Page 14: ...12 Condenser with Receiver Drier Dimensions Figure 4 Condenser with Receiver Drier Dimensions...
Page 15: ...13 HMI Dimensions Figure 5 HMI Dimensions...
Page 16: ...14 1000 Watt Power Inverter Dimensions Option Figure 6 1000 Watt Power Inverter Dimensions...
Page 18: ...16 D2 D4 Heater Dimensions Option Figure 8 Heater Dimension...
Page 19: ...17 BLANK PAGE...
Page 21: ...19 Typical Component Locations Figure 9 Typical Component Locations...
Page 45: ...43 A C Duct Installation continued FLUSH MOUNTED EVAPORATOR Figure 21 A C Duct locations...
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......