29
Evaporator/Control Box Installation (continued)
NOTE: It is not necessary to remove the Evaporator/Control Box cover to complete a system installation.
NOTE: This installation requires a two-person or mechanically assisted lift.
1.
Position template with
RETURN AIR
flush with bulkhead. Mark location of the 7/8” evaporator drain holes
and 2” access holes. Remove the template:
a.
Drill a 1/4” pilot hole for drain holes followed by a 7/8” step reamer.
b.
Drill the 2” access holes. The holes may also be located outside the template area as shown.
2.
Cut and install a piece of split loom (or similar) around the inside edge of the 2” access holes to provide
protection for hoses and wiring.
3.
Install return air filter support to front of Evaporator/Control Box.
4.
Set evaporator in place and determine where return air opening needs to be located on bulkhead. Leave
clearance for filter removal.
5.
Mark return air opening (11.00 in. x 10.00 in.).
a.
Cut opening in bulkhead.
b.
A return air grille (installer supplied) can be installed to the bulkhead if desired.
6.
Install the defrost drain tubes to the base of the evaporator before mounting to the floor.
7.
Loosely install the three mounting tabs onto the evaporator
.
8.
Secure the evaporator to the floor with TEK screws.
9.
Tighten the mounting tab bolts.
10.
From underneath the sleeper:
a.
Seal around drain tube access holes with sealing putty or silicone sealant.
b.
Apply silicone sealant around the three evaporator mounting screws.
c.
Seal any unused holes, cracks, or visible air gaps that might be found.
Figure 14: Preferred Location Shown - Flush with Front Bulkhead
Summary of Contents for TriPac Envidia
Page 2: ......
Page 11: ...9 Battery Box Dimensions Figure 1 Battery Box Dimensions...
Page 12: ...10 Battery Box Dimensions continued Figure 2 Battery Box Dimensions continued...
Page 13: ...11 Evaporator Control Box Dimensions Figure 3 Evaporator Control Box Dimensions...
Page 14: ...12 Condenser with Receiver Drier Dimensions Figure 4 Condenser with Receiver Drier Dimensions...
Page 15: ...13 HMI Dimensions Figure 5 HMI Dimensions...
Page 16: ...14 1000 Watt Power Inverter Dimensions Option Figure 6 1000 Watt Power Inverter Dimensions...
Page 18: ...16 D2 D4 Heater Dimensions Option Figure 8 Heater Dimension...
Page 19: ...17 BLANK PAGE...
Page 21: ...19 Typical Component Locations Figure 9 Typical Component Locations...
Page 45: ...43 A C Duct Installation continued FLUSH MOUNTED EVAPORATOR Figure 21 A C Duct locations...
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......