61
Priming the Heater Fuel Pump (Heat Option)
Priming the Heater Fuel System
Special Tools Required
Heater Priming Harness (204-1144)
The heater uses a pulse style fuel pump. You must use the heater priming harness to operate the fuel pump to prime the
system. Applying continuous power to the pump will not work.
NOTE: Verify there is a sufficient amount of fuel in the fuel tank.
1.
Attach the
Heater Priming Harness
connector to the heater fuel pump.
2.
Attach the alligator clips to the battery
:
Wire
Battery Connection
Red
Positive
Black
Negative
3.
Turn the priming harness switch to the
“ON”
position.
4.
The flasher unit will operate the fuel pump (ON/OFF/ON/OFF) to prime the system.
5.
Allow the system to operate for approximately 5 minutes to bleed air from the fuel lines.
NOTE: Running the fuel pump longer than 5 minutes will cause the heater to emit excessive white smoke when
operated.
6.
Check fuel lines and system for leaks.
7.
Turn the priming harness switch to the
“OFF”
position. Disconnect the positive and then the negative battery
connections.
8.
Disconnect the priming harness connector from the heater fuel pump.
9.
Attach the heater fuel pump harness onto the heater fuel pump
.
Figure 35: Priming the Heater Fuel Pump
Summary of Contents for TriPac Envidia
Page 2: ......
Page 11: ...9 Battery Box Dimensions Figure 1 Battery Box Dimensions...
Page 12: ...10 Battery Box Dimensions continued Figure 2 Battery Box Dimensions continued...
Page 13: ...11 Evaporator Control Box Dimensions Figure 3 Evaporator Control Box Dimensions...
Page 14: ...12 Condenser with Receiver Drier Dimensions Figure 4 Condenser with Receiver Drier Dimensions...
Page 15: ...13 HMI Dimensions Figure 5 HMI Dimensions...
Page 16: ...14 1000 Watt Power Inverter Dimensions Option Figure 6 1000 Watt Power Inverter Dimensions...
Page 18: ...16 D2 D4 Heater Dimensions Option Figure 8 Heater Dimension...
Page 19: ...17 BLANK PAGE...
Page 21: ...19 Typical Component Locations Figure 9 Typical Component Locations...
Page 45: ...43 A C Duct Installation continued FLUSH MOUNTED EVAPORATOR Figure 21 A C Duct locations...
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......