26
Condenser and Receiver Drier Installation
Sub-Assembly
IMPORTANT: Keep all the A/C fittings capped and sealed until the installation of the refrigeration hoses. Refrigerant
oil is extremely hygroscopic and a system left open for more than 5 minutes may require extensive evacuation /
dehydration time to remove moisture.
NOTE: Read and understand Fabricating Refrigeration Hoses on page 30 for proper hose fabrication requirements.
Always use two wrenches while tightening refrigeration fittings.
Special Tools Required
Hose Fitting Tool (204-1045)
Hose Cutting Tool (204-677)
Alkyl Benzene Refrigerant Oil (670404TKA)
Torque Wrench
Place the condenser coil onto a workbench and sub-
assemble the following components:
•
Loosely install the Ambient Temp Sensor
clamp to the receiver drier bracket.
•
Install the receiver drier bracket onto the
condenser coil housing with the Ambient Temp
Sensor clamp to the back. Use supplied 1/4-20
mounting hardware and tighten securely.
•
Attach the two large hose clamps to the
bracket.
•
Install the receiver drier to the bracket with the
hose clamps and tighten securely. Use arrow to
verify correct direction of refrigerant flow.
•
Fabricate and install a #4 hose (5.00 in. long)
with two 90 degree fittings onto the INLET
fitting of the drier and the bottom OUTLET
fitting on the condenser coil. Tighten fittings to
the torque specs shown.
Fitting Size
Torque Specifications
#6 (3/8”)
11-13 ft-lb (15-17 N•m)
#8 (1/2”)
15-20 ft-lb (20-27 N•m)
Figure 12: Refrigeration hose I.D. and sizes shown
Summary of Contents for TriPac Envidia
Page 2: ......
Page 11: ...9 Battery Box Dimensions Figure 1 Battery Box Dimensions...
Page 12: ...10 Battery Box Dimensions continued Figure 2 Battery Box Dimensions continued...
Page 13: ...11 Evaporator Control Box Dimensions Figure 3 Evaporator Control Box Dimensions...
Page 14: ...12 Condenser with Receiver Drier Dimensions Figure 4 Condenser with Receiver Drier Dimensions...
Page 15: ...13 HMI Dimensions Figure 5 HMI Dimensions...
Page 16: ...14 1000 Watt Power Inverter Dimensions Option Figure 6 1000 Watt Power Inverter Dimensions...
Page 18: ...16 D2 D4 Heater Dimensions Option Figure 8 Heater Dimension...
Page 19: ...17 BLANK PAGE...
Page 21: ...19 Typical Component Locations Figure 9 Typical Component Locations...
Page 45: ...43 A C Duct Installation continued FLUSH MOUNTED EVAPORATOR Figure 21 A C Duct locations...
Page 76: ......
Page 77: ......
Page 78: ......