27
Condenser and Receiver Drier Installation
(continued)
Installation
CAUTION: Before drilling any holes in the tractor, check for interference with internal wires, supports or interior
panels. Avoid drilling into any interior support members as this could void the tractor’s OEM warranty.
IMPORTANT: Use a backup wrench whenever tightening refrigerant hose fittings.
Special Tools Required
Template – Condenser Assembly
Tape Measure
Level
Drill Motor
3/8” Drill Bit
Caulk Gun and RTV Silicone Sealant
Locate an area on the exterior of the sleeper to install the condenser assembly that does not interfere with the operation
of existing truck components. The condenser air inlets and fan outlet airflow must not be restricted. Obstructions must
not cause recirculation of condenser out air.
If possible, mount the condenser below the bunk level. This allows easier access to 3/8” bolts with large fender washers
inside the sleeper without disturbing interior panels.
1.
Measure and mark the exterior center line of the sleeper.
2.
Position the supplied template onto the exterior of the sleeper making sure it is level and centered. Mark and
drill the 3/8” mounting holes and remove the template.
3.
Apply a bead of RTV silicone around each of the six mounting holes.
4.
Install the condenser assembly with the supplied 3/8” stainless mounting hardware.
5.
Assure all six mounting tabs are in contact with truck body. Use spacers as required.
6.
Tighten hardware securely.
Summary of Contents for TriPac Envidia
Page 2: ......
Page 11: ...9 Battery Box Dimensions Figure 1 Battery Box Dimensions...
Page 12: ...10 Battery Box Dimensions continued Figure 2 Battery Box Dimensions continued...
Page 13: ...11 Evaporator Control Box Dimensions Figure 3 Evaporator Control Box Dimensions...
Page 14: ...12 Condenser with Receiver Drier Dimensions Figure 4 Condenser with Receiver Drier Dimensions...
Page 15: ...13 HMI Dimensions Figure 5 HMI Dimensions...
Page 16: ...14 1000 Watt Power Inverter Dimensions Option Figure 6 1000 Watt Power Inverter Dimensions...
Page 18: ...16 D2 D4 Heater Dimensions Option Figure 8 Heater Dimension...
Page 19: ...17 BLANK PAGE...
Page 21: ...19 Typical Component Locations Figure 9 Typical Component Locations...
Page 45: ...43 A C Duct Installation continued FLUSH MOUNTED EVAPORATOR Figure 21 A C Duct locations...
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......