User Manual
75
DropOut Trigger
DropOut trigger includes two types: edge and state.
Edge
Trigger when the time interval (
△
T) from when the rising edge (or falling edge) of the input
signal passes through the trigger level to when the adjacent rising edge (or falling edge)
passes through the trigger level is greater than the timeout time set, as shown in the figure
below.
Trigger
Trigger
State
Trigger when the time interval (
△
T) from when the rising edge (or falling edge) of the input
signal passes through the trigger level to when the adjacent falling edge (or rising edge)
passes through the trigger level is greater than the timeout time set, as shown in the figure
below.
Trigger
Trigger
To set edge DropOut trigger:
1. Press the
Setup
button on the front panel to enter the TRIGGER system function
menu.
2. Press the
Type
softkey; then use the
Universal Knob
to select
DropOut
and push
down the knob to confirm.
3. Press the
Source
softkey; turn the
Universal Knob
to select CH1 or CH2 as the
trigger source. The current trigger source is displayed at the upper right corner of the
screen. Select channel with signal input as trigger source to obtain stable trigger.
4. Press the
Slope
softkey to select rising or falling edge.
5. Press the
OverTime Type
softkey to select
Edge
.
6. Press the
Time
softkey; turn the universal to select the desired value.
Summary of Contents for T3DSO1000
Page 1: ...User Manual T3DSO1000 T3DSO1000A Series Digital Oscilloscope...
Page 62: ...44 User Manual Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Page 90: ...72 User Manual Figure 32 Relative Window Trigger...
Page 92: ...74 User Manual Figure 33 Interval Trigger...
Page 98: ...80 User Manual Universal Knob to select the desired value Figure 37 Pattern Trigger...
Page 118: ...100 User Manual Figure 50 UART Trigger...
Page 145: ...User Manual 127 function output Figure 63 Square Root...
Page 205: ...User Manual 187 Figure 100 Option Information...