CAN Triggering
This part will provide a brief introduction and description for the operation of the LIN
trigger.
To introduce the trigger conditions
●
Start
— the oscilloscope will be triggered at the start bit of a frame.
●
Remote
— the oscilloscope will be triggered by a remote frame with specified ID.
●
ID
— the oscilloscope will be triggered by a remote or data frame that has s specified
ID.
●
ID+DATA
— the oscilloscope will be triggered by a data frame that has a specified
ID and data.
●
Error
— the oscilloscope will be triggered by an error frame.
Operation steps:
1. Press
Setup
to enter the
TRIGGER
function menu.
2. Press
Type
and select
Serial
.
3. Press
Protocol
and select
CAN
.
4. Press
Trigger Setting
to enter the
CAN TRIG SET
menu.
5. Press
Condition
and select the trigger condition using the Universal Knob:
●
If you select the
REMOTE
and
ID
condition:
a. Press
ID Bits
to set the length of the ID (11bits or 29 bits).
b. Press
Curr ID Byte
and use Universal Knob to select the byte that you want
to set.
c. Press the
ID
and set the ID’s value using the Universal Knob.
(
Tips
: In order to make it convenient for the operator to set the parameters, ID
length is split into several bytes. For example, if the ID’s length is 11 bits, it will be
split into two bytes, a byte is 8 bits. If “1st byte” is selected, only the 8 least
Summary of Contents for T3DSO1000
Page 1: ...User Manual T3DSO1000 T3DSO1000A Series Digital Oscilloscope...
Page 62: ...44 User Manual Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Page 90: ...72 User Manual Figure 32 Relative Window Trigger...
Page 92: ...74 User Manual Figure 33 Interval Trigger...
Page 98: ...80 User Manual Universal Knob to select the desired value Figure 37 Pattern Trigger...
Page 118: ...100 User Manual Figure 50 UART Trigger...
Page 145: ...User Manual 127 function output Figure 63 Square Root...
Page 205: ...User Manual 187 Figure 100 Option Information...