User Manual
91
Figure 43 CLK Menu
6.
Set MISO:
a.
Press the
MISO
softkey to enter the MISO menu.
b.
Press the
MISO
softkey to select the channel that is connected to the SPI MISO
signal.
c.
Press the
Threshold
softkey to set the SPI MISO signal’s threshold voltage level
using the Universal Knob. The threshold voltage level is for decoding, and it will
be used as the trigger voltage level when setting the trigger type to serial.
d.
Press
softkey to return previous menu.
Figure 44 MISO Menu
7.
Set MOSI:
a.
Press the
MOSI
softkey to enter the MOSI menu.
b.
Press the
MOSI
softkey to select the channel that is connected to the SPI MOSI
signal.
c.
Press the
Threshold
softkey to set the SPI MOSI signal’s threshold voltage level
using the Universal Knob. The threshold voltage level is for decoding, and it will
be used as the trigger voltage level when setting the trigger type to serial.
d.
Press
softkey to return previous menu.
Figure 45 MOSI Menu
8.
Set CS:
a.
Press the
CS
softkey to enter the MOSI menu.
b.
Press the
CS Type
softkey to select the chip select type.
c.
Modify the CS type’s value.
d.
Press
softkey to return previous menu.
Summary of Contents for T3DSO1000
Page 1: ...User Manual T3DSO1000 T3DSO1000A Series Digital Oscilloscope...
Page 62: ...44 User Manual Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Page 90: ...72 User Manual Figure 32 Relative Window Trigger...
Page 92: ...74 User Manual Figure 33 Interval Trigger...
Page 98: ...80 User Manual Universal Knob to select the desired value Figure 37 Pattern Trigger...
Page 118: ...100 User Manual Figure 50 UART Trigger...
Page 145: ...User Manual 127 function output Figure 63 Square Root...
Page 205: ...User Manual 187 Figure 100 Option Information...