90 User Manual
SPI Triggering and Serial Decode
Three simple steps are necessary to trigger and decode the signals: “
Setup for SPI
Signals
”, “
SPI Triggering
” and “
SPI Decode
” to trigger and decode the signals.
Setup for SPI Signals
Setting the SPI (Serial Peripheral Interface) signal includes two steps: connecting the
CLK, MISO, MOSI and CS signals to oscilloscope; specifying the parameters of each
input signal.
1.
Press the
Decode
key to enter the
DECODE
function menu.
2.
Press the
Decode
softkey and select the desired decoder (Decode1 or Decode2).
3.
Press
Protocol
softkey and then select
SPI
by turning the Universal Knob.
4.
Press
Signal
softkey to enter the
SIGNAL
menu as Figure 42 shows.
Figure 42 SIGNAL Menu
5.
Set CLK (clock signal):
a.
Press the
CLK
softkey to enter
CLK
menu.
b.
Press the
CLK
softkey to select the channel that is connected to the SPI clock
signal.
c.
Press the
Threshold
softkey to set the SPI clock signal’s threshold voltage level
using the Universal Knob. The threshold voltage level is for decoding, and it will
be used as the trigger voltage level when setting the trigger type to serial.
d.
Press the
Edge Select
softkey to set the oscilloscope to sample at the
clock signal’s rising edge or falling edge.
e.
Press
softkey to return to the previous menu.
Summary of Contents for T3DSO1000
Page 1: ...User Manual T3DSO1000 T3DSO1000A Series Digital Oscilloscope...
Page 62: ...44 User Manual Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Page 90: ...72 User Manual Figure 32 Relative Window Trigger...
Page 92: ...74 User Manual Figure 33 Interval Trigger...
Page 98: ...80 User Manual Universal Knob to select the desired value Figure 37 Pattern Trigger...
Page 118: ...100 User Manual Figure 50 UART Trigger...
Page 145: ...User Manual 127 function output Figure 63 Square Root...
Page 205: ...User Manual 187 Figure 100 Option Information...