28 User Manual
To Specify Channel Coupling
Set the coupling mode to filter out the undesired signals. For example, the signal under
test is a square waveform with DC offset.
●
When the coupling mode set to
DC
: the DC and AC components of the signal under
test can both pass into the scope measurement channel.
●
When the coupling mode set to
AC
: the DC components of the signal under test are
blocked.
●
When the coupling mode set to
GND
: the DC and AC components of the signal under
test are both blocked.
Press the
CH1
button on the front panel; then press the
Coupling
softkey and turn the
Universal Knob
to select the desired coupling mode. The default setup is
DC
.
The current coupling mode is displayed in the channel label at the right side of the screen.
You can also press the
Coupling
softkey continuously to switch the coupling mode.
To Specify Bandwidth Limit
Set the bandwidth limit to reduce display noise. For example, the signal under test is a
pulse with high frequency oscillation.
●
When the bandwidth limit set to
Full
, the high frequency components of the signal
under test can pass into the scope measurement channel.
●
When the bandwidth limit set to
20M
, the high frequency components that exceed 20
MHz are attenuated.
Press the
CH1
button on the front panel; then press the
BW Limit
softkey to select
Full
or
20M
. The default setup is
Full
. When bandwidth limit is enabled, the character
B
will be
displayed in the channel label at the right side of the screen.
T3DSO1000 series has full BW at all V/div settings including 500uV/div to 2mV/div.
Summary of Contents for T3DSO1000
Page 1: ...User Manual T3DSO1000 T3DSO1000A Series Digital Oscilloscope...
Page 62: ...44 User Manual Figure 16 x Interpolation Figure 17 Sinx x Interpolation...
Page 90: ...72 User Manual Figure 32 Relative Window Trigger...
Page 92: ...74 User Manual Figure 33 Interval Trigger...
Page 98: ...80 User Manual Universal Knob to select the desired value Figure 37 Pattern Trigger...
Page 118: ...100 User Manual Figure 50 UART Trigger...
Page 145: ...User Manual 127 function output Figure 63 Square Root...
Page 205: ...User Manual 187 Figure 100 Option Information...