Table A-1: T300/T300M and M300E/EM Setup Variables, Revision L.8
Setup Variable
Numeric
Units
Default
Value
Value
Range
Description
Low Access Level Setup Variables (818 password)
DAS_HOLD_OFF
Minutes
15
0.5–20
Duration of DAS hold off period.
CONC_PRECISION — 3 AUTO,
0,
1,
2,
3,
4
Number of digits to display to the
right of the decimal point for
concentrations on the display.
REM_CAL_DURATION
17
Minutes 20
1–120 Duration of automatic calibration
initiated from TAI protocol.
STABIL_GAS —
CO
0
CO,
CO2
10
,
O2
14
Selects gas for stability
measurement.
DYN_ZERO —
OFF
ON,
OFF
ON
enables remote dynamic
zero calibration;
OFF
disables it.
DYN_SPAN —
OFF
ON,
OFF
ON
enables remote dynamic
span calibration;
OFF
disables it.
CLOCK_ADJ Sec./Day
0
-60–60
Time-of-day clock speed
adjustment.
Medium Access Level Setup Variables (929 password)
LANGUAGE_SELECT — ENGL
0
ENGL,
SECD,
EXTN
Selects the language to use for
the user interface.
MAINT_TIMEOUT Hours
2 0.1–100
Time until automatically
switching out of software-
controlled maintenance mode.
CONV_TIME —
33
MS
0
33
MS,
66 MS,
133 MS,
266 MS,
533 MS,
1 SEC,
2 SEC
Conversion time for
measure/reference detector
channel.
CO_DWELL Seconds
0.2
0.1–30
Dwell time before taking
measure or reference sample.
CO_SAMPLE Samples
1
1–30
Number of samples to take in
measure or reference mode.
PRE_FILT_SIZE
5, 19
Samples
16
1–50
Moving average pre-filter size.
FILT_SIZE Samples
750,
720
9, 12
200
3, 8
1000
19, 23
1–1000
Moving average filter size.
06864B DCN6314
Summary of Contents for T300
Page 2: ......
Page 12: ...Teledyne API Model T300 T300M CO Analyzer x This page intentionally left blank 06864B DCN6314 ...
Page 25: ...23 PART I GENERAL INFORMATION 06864B DCN6314 ...
Page 26: ...24 06864B DCN6314 ...
Page 89: ...87 PART II OPERATING INSTRUCTIONS 06864B DCN6314 ...
Page 90: ...Getting Started Teledyne API Model T300 T300M CO Analyzer 88 06864B DCN6314 ...
Page 243: ...241 PART III TECHNICAL INFORMATION 06864B DCN6314 ...
Page 244: ...06864B DCN6314 ...
Page 245: ...243 06864B DCN6314 ...
Page 246: ...06864B DCN6314 ...
Page 386: ...This page intentionally left blank B 2 06864B DCN6314 ...
Page 395: ...APPENDIX D Wire List and Electronic Schematics 06864B DCN6314 D 1 ...
Page 396: ...This page intentionally left blank D 2 06864B DCN6314 ...
Page 400: ...This page intentionally left blank D 6 06864B DCN6314 ...
Page 401: ...06864B DCN6314 D 7 ...