2-91
Cable Connections
Frame Power Supply Connections
1.
Ensure that the power switch located on the front of the Frame power supply
is in the OFF position.
2.
Connect the power cable from the rear of the Frame Power Supply to an
appropriate source of 220VAC power. Refer to
requirements.
3.
Make sure you have the correct power cable. For use in Europe you should
have received a power cable with pigtails on the free end. For use in the U.S.,
Canada, South America and Southeast Asia the power cable should have a 20
Amp Twist-Lock 240 VAC NEMA Type l6-20P plug attached as illustrated in
4.
If a redundant Frame Power Supply is installed, connect it to a separate power
source (branch circuit).
Processor
Power Plug
20 Amp
Twist-Lock
240V AC
NEMA Type
L6-20P
Plug
(Male Plug)
L1
Ground
L2
M22-003-47
Figure 2-53. AC Power Connector