2-26
Section 2 — Installation
3.
In the center section, disconnect the incoming AC power wires from the left
and right sides of the terminal block (see
).
4.
Remove the hardware fastening the incoming AC power cable ground wire to
the chassis ground stud and disconnect that wire. Also remove the jumper
wire which ties the stud to the terminal block.
5.
Unscrew the knurled cord retainer and remove the 10 AWG power cord.
6.
Remove the power cord retention block from the supply chassis.
7.
The 6 AWG wiring may now be installed (see
a 3/4-inch (19 cm) electrical conduit fitting be installed in the hole from which
the power cord retention block was removed and the wiring be routed in
through flexible conduit from a junction box. In the United States, field wiring
Remove 10 AWG
Power Cord
(3 wires) and
Hardware
Remove
Nut and
Jumper
Wire
L1
L2
Blue
Brown
Green/Yellow
0347-0232
Figure 2-15. For 110 Vac Operation – Remove 220 Vac Wiring