2-46
Section 2 — Installation
Chroma Key Input Modules—
The Dual Analog Component Chroma Key Input
option includes up to three Chroma Key Input Modules (064817) with mezzanine
boards (064837), each with two full bandwidth component analog inputs that can
be routed to any Chroma Keyer in the system.
The Chroma Key Input Modules reside in the lower rear D Bay in slots D7, D8, and
D9. Refer to Table 2-6 and
for module locations. Input signals to the
modules can be in the same formats as the Analog Input Module listed above.
The input parameters for Chroma Key Inputs must be defined in the
configurations menus. These menus appear in Confg/Inputs/Chr Key Inputs.
Refer to the Model 4000 User’s Guide (TP0790) and Operation Reference (TP0764)
Manuals for detailed information.
Important timing considerations for Chroma Key Inputs are also discussed later in
this procedure in the “System Timing” section (see
Table 2-6. Chroma Key Input Module Locations
Chroma Key Input
Bay D Module Location
1 and 2
Slot D9
3 and 4
Slot D8
5 and 6
Slot D7