2-63
Cable Connections
Control Panel Connections
The control panel communicates with the Signal Processor Frame over
RS-422 data lines–one per M/E plus a flip/flop mix data link. All of the links are
contained in a single RP125 parallel digital cable that may be up to 300 meters (985
feet) long. Standard jacketed (PVC) and plenum rated (Teflon®) cables are
available.
The pinout for the parallel digital cables is illustrated in
Length as
Specified
CF1597
Connector
Ferrule
(2)
CF1595
Connector
Hood
(2)
CA4113-01
Cable
CF1593
25-Pin
Male
Connector
(2)
123
4
5678
9
1
0
1
1
1
2
1
3
14
15
16
17
18
19
20
21
22
23
24
25
123
4
5678
9
1
0
1
1
1
2
1
3
14
15
16
17
18
19
20
21
22
23
24
25
Male
AMP 207464-2
Wiring Side
Male
AMP 207464-2
Wiring Side
Twisted
Pairs
BLUE-BLACK
BLACK-BLUE
YELLOW-BLACK
BLACK-YELLOW
RED-BROWN
BROWN-RED
BROWN-BLACK
BLACK-BROWN
ORANGE-BLACK
BLACK-ORANGE
WHITE-BLACK
BLACK-WHITE
WHITE-RED
RED-WHITE
GREEN-BLACK
BLACK-GREEN
BLUE-RED
RED-BLUE
RED-BLACK
BLACK-RED
GREEN-RED
RED-GREEN
RED-YELLOW
YELLOW-RED
DRAIN WIRE
0625-01-05
NOTE: Wire gauge is 28 AWG for lengths
up to 15 meters; use 26 AWG for lengths
greater than 15 meters.
All connections
have a 1:1
correspondence
(pin 1 connects
to pin 1; pin 14
to pin 14; etc.)
Figure 2-34. Control Panel to Frame RP125 Digital Cable
Summary of Contents for Grass Valley 4000
Page 3: ...iii Tektronix Grass Valley Products P O Box 1114 Grass Valley CA 95945 916 478 3800 ...
Page 4: ...iv Tektronix Grass Valley Products P O Box 1114 Grass Valley CA 95945 916 478 3800 ...
Page 34: ...1 20 Section 1 System Overview ...
Page 138: ...2 104 Section 2 Installation ...
Page 196: ...3 58 Section 3 Functional Description ...