2-27
Installation
must be in compliance with the National Electrical Code and any applicable
local codes.
8.
Connect the incoming “safety ground” wire to the center terminal of the
terminal block.
9.
Connect the “neutral” side of the incoming AC power to the side of the
terminal block associated with the blue wire
10. Connect the “line” side of the incoming AC power to the side of the terminal
block associated with the brown wire.
11. Inspect your work to make sure that all connections are correct, tight, and safe.
12. Reinstall the center cover plate, putting in the four screws at the top and the
three screws at the bottom.
Install 3/4 In.
Conduit Fitting
in Cable Hole
Install Cable or
Flexible Conduit
With 6 AWG Wire
Directly From
Circuit Breaker
Install 3-Wire
6 AWG Cable
"Line"
"Safety Ground"
"Neutral"
L2
L1
Blue
Brown
Green/Yellow
0347-0233
Figure 2-16. For 110 Vac Operation – Install 110 Vac Wiring