2-16
Section 2 — Installation
NOTE:
You may choose to install the redundant supply power into a different ac source
than the primary power supply; however, doing this is not required.
11. Reinstall the ac power cord for the primary supply into its ac source.
12. If you have installed this option into an existing system, turn on both power
supply switches for operation. No power supply adjustments are required at
this time.
0621-212
Control Panel
CPU Board
Power
ON/OFF
Switch
Fuse
Standard
Supply
Redundant
Supply
Control Panel
I/O Board
(068949)
EMI
Filter
Power
ON/OFF
Switch
(Redundant)
Fuse
(Redundant)
Mounting Plate
Power
Supply
Enclosure
(secured
by 6 screws)
Exhaust
Fan
(MODEL 4000-2A)
Figure 2-10. Model 4000-2A/B Panel Redundant Power Supply Installation
Summary of Contents for Grass Valley 4000
Page 3: ...iii Tektronix Grass Valley Products P O Box 1114 Grass Valley CA 95945 916 478 3800 ...
Page 4: ...iv Tektronix Grass Valley Products P O Box 1114 Grass Valley CA 95945 916 478 3800 ...
Page 34: ...1 20 Section 1 System Overview ...
Page 138: ...2 104 Section 2 Installation ...
Page 196: ...3 58 Section 3 Functional Description ...
Page 286: ...Index 6 Index ...