3-3
System Overview
Control Panel
The control panels for the Model 4000 systems contain circuit boards for
controlling the panel functions.
■
Input Voltages: 120 to 240 volts nominal (auto-ranging)
■
Operating voltages: +5V and +14V
Signal Paths
The video takes one of the following paths (See
The normal path is:
■
Input Module
■
Crosspoint Module
■
Keyer Module
■
Mixer Interface Module
■
Mix/Wipe Module
■
Output Module
For reentry signals, the path is the same as the normal path except that instead of
going to the output module, the signal is routed to a reentry module then back into
the crosspoint module.
For effects send, the signals use the following path:
■
Input Module
■
Crosspoint Module
■
Keyer Module
■
Mixer Interface Module
■
Effects Send Module
■
Output Module
This will send the video and key out on an aux bus to a DVE.
The return signal path for the modified video and key is:
■
Input module
■
Crosspoint Module
■
Effects Send Module
■
Mixer Interface Module
■
Mix/Wipe Module