3-57
Power Supply Description
Remote Aux Panel
Each of the Remote Aux Control Panels contains two printed circuit modules. The
Switch Module, which is different for each Remote Aux system, and the CPU
Module, which is identical in each system.
■
068965 a one rack unit Remote Aux Switch Module
■
068963 a two rack unit Remote Aux Switch Module
■
068964 a three rack unit Remote Aux Switch Module
■
068966 a Remote Aux CPU Module
The CPU module contains the back panel setup switches, switch decoders, the
communications interface, and the lamp and switch interface. The CPU Module
contains the power supply for both modules in the system. The input +12 Volts
uses a 2 Amp fuse, and a 5 Volt regulator. The +5 Volts powers the processor
module, and the +5 and +12 Volts power the Switch Module.
The Switch Module contains the switch and lamp decoding circuitry.