Section 2 — Installation
Maintenance Terminal Connections
The Maintenance port allows a text-only monitor to be connected to the Model
4000. The monitor is normally used for maintenance purposes only.
1.
Connect a cable from the input port of a RS-232 terminal to J1
(MAINTENANCE port) on the GPI Module in Slot C4. See
The Data cable must be wired in a standard RS-232 configuration with pin
assignments as follows:
■
Pin 1
— Protective Ground
■
Pin 2
— TxD (From the Terminal)
■
Pin 3
— RxD (To the Terminal)
■
Pin 7
— Signal Ground
2.
Ensure that the baud rate of the terminal matches the parameters of the Model
4000 given below.
■
9600 baud
■
8 data bits
■
1 stop bit
■
No parity
See the monitor’s manual for its settings.
Power Connections to Control Panel and Frame
Control Panel Power Supply Connections
1.
Open the Control Panel lid and check to see that the power switch (located on
the left side of the tub) is in the OFF position.
2.
Connect the power cable from the back of the Control Panel to source power.
Do NOT turn Control Panel power on at this time.
3.
Verify you have received the correct power cable. For use in Europe, the power
cables must be TUV approved. The Control Panel power cable should be a
molded grounding connector (IEC 320-C13) on one end with pigtails on the
other.
4.
For use in the United States, Canada, South America and Southeast Asia, a
standard 110VAC power cable is supplied for the Control Panel. It has a
molded grounding plug (NEMA 5-15P) at one end and a molded grounding
connector (IEC 320-C13) at the other end.
Summary of Contents for Grass Valley 4000
Page 3: ...iii Tektronix Grass Valley Products P O Box 1114 Grass Valley CA 95945 916 478 3800 ...
Page 4: ...iv Tektronix Grass Valley Products P O Box 1114 Grass Valley CA 95945 916 478 3800 ...
Page 34: ...1 20 Section 1 System Overview ...
Page 138: ...2 104 Section 2 Installation ...
Page 196: ...3 58 Section 3 Functional Description ...
Page 286: ...Index 6 Index ...