2-66
Section 2 — Installation
Status Terminal Connections
The Status Terminal connector (labeled “MAINTENANCE”) on the rear of the
Control Panel allows the connection of a VT-100 (type) terminal to be connected to
the Model 4000. The terminal is used to monitor system status and for maintenance
purposes.
1.
Connect a cable between the input of a VT-100 (type) terminal and J3 (Status
Terminal connector) on the rear of the Control Panel. The connector (J3) on the
rear of the Control Panel is a standard RS-232 configuration via a DB-25
connector with the following pin-outs:
■
Pin 1
— Protective Ground
■
Pin 2
— TxD (From the Terminal)
■
Pin 3
— RxD (To the Terminal)
■
Pin 7
— Signal Ground
2.
Ensure that the baud rate and other parameters of the Model 4000 given below
match the baud rate of the terminal. See the Owner’s Manual of the terminal
in use to determine or set the baud rate of the terminal. Also be sure the
terminal is set to “Newline Off” or “No Newline”.
■
9600 baud
■
8 data bits
■
1 stop bit
■
No parity
Summary of Contents for Grass Valley 4000