2-3
Pre-installation Procedures
Power Requirements
Power requirements for the Model 4000 Control Panel and Signal Processing
Frames are listed in
. The Frame is shipped from the factory configured
for 220 VAC operation.
Environmental Characteristics
The Model 4000 has been designed to operate efficiently in environments outlined
below in
.
Safety Requirements
The following precautions are provided to ensure that safety considerations for
both equipment and personnel are presented before any installation procedures
are begun. To prevent injury or equipment damage, read, understand, and follow
all installation safety precautions.
Table 2-2. Power Requirements
Component
Power
Voltage
Frequency
Control Panel
300 Watts (max)
110/220 VAC (nominal)
50-60 Hz
Signal Processor
Power Supply
1800 Watts (Typical)
2500 Watts (Fully Optioned)
1300 Watts (No Options)
176-264 VAC or
100-264 VAC
1
1.
Model 4000-2A/B only with auto-ranging power supply P/N 098901-03
50-60 Hz
Table 2-3. Environmental Characteristics
Characteristic
Requirement
Operating ambient temperature
0 - 40 ° C (32 - 104 ° F)
Ambient temperature for specifications
20 -30 ° C (68 - 86 ° F)
Relative humidity
95% max (non-condensing)
Summary of Contents for Grass Valley 4000
Page 3: ...iii Tektronix Grass Valley Products P O Box 1114 Grass Valley CA 95945 916 478 3800 ...
Page 4: ...iv Tektronix Grass Valley Products P O Box 1114 Grass Valley CA 95945 916 478 3800 ...
Page 34: ...1 20 Section 1 System Overview ...
Page 138: ...2 104 Section 2 Installation ...
Page 196: ...3 58 Section 3 Functional Description ...
Page 286: ...Index 6 Index ...