(16) Multi-Function Analog Input Selection (Sn-19)
• The settings and functions for the multi-function analog input (terminal AUX) are listed as below.
SET
VALUE
FUNCTION
LCD DISPLAY (ENGLISH)
REMARKS
00
AUX frequency reference*
Auxiliary Freq. Cmd.
Used for MASTER/AUX frequency reference selection
01
Frequency reference gain
(F GAIN)
~ Freq. Cmd. Gain
Total gain: Internal gain (bn-05) × F GAIN
02
Frequency reference bias 1
(F BIAS 1)
Cmd. Bias 1
Total bias: Internal bias (bn-06) + F BIAS 1
03
Frequency reference bias 2
(F BIAS 2) (+ -)
Cmd. Bias 2
Total bias: Internal bias (bn-06) + F BIAS 2
04
Overtorque detection level
Over Tq. Level
Internal over torque detection level (Cn-26) ineffective
05
V BIAS †
V/F curve Bias
V BIAS addition after V/F conversion
06
Accel/decel time reduction
coefficient
Acc.&Dec. coeff.
Accel/decel time varied by the analog input
07
DC braking current
DC Braking current
DC injection braking current varied by the analog input
(10 V/AC Drive rated current) Internal DC braking
current setting (Cn-11) ineffective
08
Stall level during run
Run stall Level
Stall level during running is set by analog input.
Cn- 30 becomes ineffective.
09
PID control selection
PID Command
PID control active
0A
Frequency reference lower limit Freq. Cmd. Low Bound
Frequency reference lower value is set by analog input. (Either Cn-15 set
value or analog input whichever is larger becomes effective.)
0B
Setting prohibit frequency 4 Freq. Jump 4
Set prohibit frequency is set. (The fourth value in addition to frequency
values set by Cn-16 to 18 can be set)
0C
Motor overheat protection
MTR OH protect
Motor temperature sensor PTC thermistor connected to terminal
MT-AUX and GND. Motor overheat protection active when the
resistor of PTC thermistor ≥1330Ω, return when ≤ 550Ω
0D~0F
Not used
Reserved
–
* Not to be used with An-02
460 class: V BIAS value 0 to 200 V.
Note: For combinations of multi-step speed references at set value = 00. refer to pages 2-46 and 2-47
.
2-56
PA 7300
PART II: OPERATION MANUAL
Summary of Contents for PA7300 Series
Page 9: ......
Page 10: ...PART I INSTALLATION MANUAL ...
Page 44: ...PART II OPERATION MANUAL ...
Page 107: ...2 57 PA 7300 PART II OPERATION MANUAL REDUCTION COEFFICIENT ...
Page 116: ...2 66 PA 7300 PART II OPERATION MANUAL 2 5 Monitoring Peramiters UN ...
Page 117: ...2 67 PA 7300 PART II OPERATION MANUAL ...
Page 150: ...i PA 7300 INSTRUCTION MANUAL ...
Page 151: ...i PA 7300 INSTRUCTION MANUAL ...
Page 152: ...i PA 7300 INSTRUCTION MANUAL ...
Page 153: ...i PA 7300 INSTRUCTION MANUAL ...
Page 154: ...5100 N IH 35 Round Rock Texas 78681 USA 1 800 279 4007 www tecowestinghouse com ...