11 FJOG command, RJOG command (set value = 12, 13)
• Forward and reverse jog frequency operation is enabled.
Set value = 12 FJOG command: Forward run by the jog frequency reference (An-09) when closed.
Set value = 13 RJOG command: Reverse run by the jog frequency reference (An-09) when closed.
Notes:
1. When the FJOG command or RJOG command is asserted during run, the FJOG command or RJOG
command has priority
2. When both FJOG and RJOG commands are closed for 500 ms or more, the AC drive stops according to
the stopping method selected in (Sn-04).
3. FJOG or RJOG commands can be set individually.
12 External faults 5 to 8 (set values = 2X, 3X, 4x, 5X: X is 0 to F)
• When external faults 5 to 8 are asserted, Ext. Faults, 5 to 8 (EF5 to EF8) are displayed at the digital
operator, and the AC drive operates according to combinations of four bits shown in the table
below. The hexadecimal equivalent of combinations of the four bits show below are set in the 1st
digit (x) (2X, 3X, 4X, 5X) of external faults 5 to 8.
Bit No.
0
1
0
External fault input:
External fault input
NO - contact input
NC - contact input
1
External fault signal:
External fault signal
Always detected
Detected during running only
3, 2
Selection of processing
00: Ramp to a stop (major fault)
at external fault detection
01: Coasting to a stop (major fault)
10: Ramp to a stop by bn-04 (major fault)
11: Operation to continue (minor fault)
<Example> External fault 5 is set to as follows :
--- NO-contact input (from terminal 5)
--- Signal is always detected
--- AC Drive will coast to a stop
2-52
PA 7300
PART II: OPERATION MANUAL
Summary of Contents for PA7300 Series
Page 9: ......
Page 10: ...PART I INSTALLATION MANUAL ...
Page 44: ...PART II OPERATION MANUAL ...
Page 107: ...2 57 PA 7300 PART II OPERATION MANUAL REDUCTION COEFFICIENT ...
Page 116: ...2 66 PA 7300 PART II OPERATION MANUAL 2 5 Monitoring Peramiters UN ...
Page 117: ...2 67 PA 7300 PART II OPERATION MANUAL ...
Page 150: ...i PA 7300 INSTRUCTION MANUAL ...
Page 151: ...i PA 7300 INSTRUCTION MANUAL ...
Page 152: ...i PA 7300 INSTRUCTION MANUAL ...
Page 153: ...i PA 7300 INSTRUCTION MANUAL ...
Page 154: ...5100 N IH 35 Round Rock Texas 78681 USA 1 800 279 4007 www tecowestinghouse com ...