Coral IPx Office Installation Manual
Hardware Installation Procedure
2-47
Eq
uipment Insta
llation
2
DC Powered Systems
This section describes how to connect the power wires to the Coral IPx Office unit for
DC powered systems (that is, when the PS Office DC power supply card is installed
in the unit).
shows one IPx Office unit installed within the system, and
shows three units installed within the system.
The DC power wires provided with the system are 6.6ft (2m) long. Verify that
the connection to the facilities power source is made according to local
requirements.
1.
The PS Office DC power supply unit is supplied with a 6.6ft (2m) long pair of
16 AWG wires (one red and one black). If this is not long enough to connect
the facilities power source to the cage, fabricate an extension at the customer’s
site with two wires that are identical to the ones above.
2.
Route each power wire to the DC connection on the front panel of the
PS Office DC. Take care not to let the free end of the cable cause damage by
swinging loose or making contact with another electrical connection.
3.
Do
not
insert the DC power input connector at this time. Leave the DC power
input connector unplugged.
4.
Connect the other ends of the wires to the –48VDC facilities power source and
a circuit breaker as shown in
and
and according to
local regulatory requirements.
Negative (black) wire to the circuit breaker or –48V busbar panel
Positive (red) wire to the +48VDC terminal or +48V busbar panel
Summary of Contents for Coral IPx Office
Page 2: ......
Page 4: ......
Page 25: ...xxi Figure 11 10 WiFi Antenna Removal 11 18...
Page 26: ......
Page 28: ......
Page 36: ...1 8 Introduction Coral IPx Office Installation Manual About this Manual 1 NOTES...
Page 44: ......
Page 96: ......
Page 106: ...3 10 Initial Power up Tests Coral IPx Office Installation Manual Common Control Test 3 NOTES...
Page 122: ......
Page 138: ......
Page 182: ......
Page 234: ......
Page 258: ...7 24 Power Supply Coral IPx Office Installation Manual PS Office DC Power Supply Unit 7 NOTES...
Page 260: ......
Page 302: ...8 42 Common Control Cards Coral IPx Office Installation Manual Compact Flash Disk 8 NOTES...
Page 310: ...8 50 Common Control Cards Coral IPx Office Installation Manual DBM Card 8 NOTES...
Page 312: ......
Page 372: ...9 60 Shared Service Cards Coral IPx Office Installation Manual VoIP Media Gateway MG 9 NOTES...
Page 420: ......
Page 488: ......
Page 509: ......