2-28
Hardware Installation Procedure
Coral IPx Office Installation Manual
Eq
uipment Insta
llation
2
2.
If IPx 500X expansion cages are installed, determine the position of peripheral
interface cards that will be inserted into card slots 1 through 10 in the
expansion cage. Observe any order previously directed by a system designer or
any established convention of the distributor. Card placement diagrams shown
on
and
may be used as a worksheet by the system
designer to establish card placement prior to installation. Refer to the
Coral
IPx 500 Installation Manual Chapter 2
and the
Coral Service and Peripheral
Cards Installation Manual
.
Place digital trunk interface cards in card slots 4 and/or 5. Slots 4 and 5 are
wired as the primary and secondary external clock source, respectively. The
cards inserted in these slots can be used to synchronize the Coral IPx system
clock with a network clock signal derived from a digital trunk circuit.
If no other convention exists, refer to
Section 10, Peripheral Cards Installation
of the
Coral IPx 500 Installation Manual
.
3.
If IPx 800X expansion cages are installed, determine the position of service
and peripheral interface cards that will be inserted into card slots 1 through 12.
Observe any order previously directed by a system designer or any established
convention of the distributor. Card placement diagrams
through
may be used as a worksheet by the system designer to establish
card placement prior to installation. Refer to
Coral IPx 800 Installation
Manual - Section-2
and
Coral Service and Peripheral Cards Installation
Manual
. If no other convention exists, plan the card placement as follows:
In a system with one expansion cage, insert a shared service card into slot 1
of the expansion cage.
In a system with two IPx 800X expansion cages, insert a PX card into slot
1 of the first expansion cage, and insert a shared service card into slot 1 of
the second expansion cage.
Insert the digital trunk interface cards into slots 4 and 5 of the designated
cage(s). Slots 4 and 5 are wired as the primary and secondary external
clock source, respectively. The cards inserted in these slots can be used to
synchronize the Coral system clock with a network clock signal via a
digital trunk circuit. Refer to
Digital Trunk Synchronization, page 10-15
and
Coral Synchronization via Digital Trunks
section in the
Coral Service
and Peripheral Cards Installation Manual
, for more information on
synchronization.
Insert peripheral cards into slots 2 through 12 of the expansion cages.
Summary of Contents for Coral IPx Office
Page 2: ......
Page 4: ......
Page 25: ...xxi Figure 11 10 WiFi Antenna Removal 11 18...
Page 26: ......
Page 28: ......
Page 36: ...1 8 Introduction Coral IPx Office Installation Manual About this Manual 1 NOTES...
Page 44: ......
Page 96: ......
Page 106: ...3 10 Initial Power up Tests Coral IPx Office Installation Manual Common Control Test 3 NOTES...
Page 122: ......
Page 138: ......
Page 182: ......
Page 234: ......
Page 258: ...7 24 Power Supply Coral IPx Office Installation Manual PS Office DC Power Supply Unit 7 NOTES...
Page 260: ......
Page 302: ...8 42 Common Control Cards Coral IPx Office Installation Manual Compact Flash Disk 8 NOTES...
Page 310: ...8 50 Common Control Cards Coral IPx Office Installation Manual DBM Card 8 NOTES...
Page 312: ......
Page 372: ...9 60 Shared Service Cards Coral IPx Office Installation Manual VoIP Media Gateway MG 9 NOTES...
Page 420: ......
Page 488: ......
Page 509: ......