Sunny Boy 700
Technical Description
SB700-11:EE
-
75
-
SMA Regelsysteme GmbH
Fig. 9.2: Input current as a function of input voltage of the Sunny Boy
The inverter is not damaged if the input current supplied by the
connected PV panel exceeds the maximum that can be used. How-
ever the input voltage has to be within the admissible input voltage
range.
All pole disconnection on DC side:
MC plug connector
Over-voltage protection:
thermally monitored varistors
Voltage ripple:
U
pp
< 10%
Personnel protection:
earth fault monitoring
(R
iso
> 1 M
Ω
)
Pole confusion prevention:
short circuit diode