Sunny Boy 700
Technical Description
SB700-11:EE
-
60
-
SMA Regelsysteme GmbH
Follow ESD protection countermeasures when modifying the Sunny Boy:
Electronic components are sensitive to electrostatic discharge. To protect them you
have to be on the same electric potential. Discharge the electrostatic charge by
touching the grounded case before touching an electronic component, otherwise you
take a great risk in destroying your electronics.
Open the device as described in chapter 5.1.
Remove the piggy back that is installed on the system control board.
•
Only for installation of an RS232 or RS485 board:
−
Remove the resistors (Fig. 6.6) on the system control board by cutting
them out with a wire cutter.
•
Only for installation of a board for Powerline Communication:
−
Please make sure that the resistors (Fig. 6.6) are plugged onto the system
control board. If not, resistors (corresponding to 0 Ohm resistors) have to
be installed in there.
Plug the desired piggy back module onto the required slot. When plugging on the
piggy back please make sure no socket of the piggy back plug-in contacts remains
open.
Connect the cables for RS232 (see Fig. 6.3) or RS485 (see Fig. 6.6). No cabling is
necessary for Powerline communication. Data cables are lead outside through the
free opening at the bottom of the Sunny Boy. Please insert the PG16 screws into this
opening and fasten them.