Sunny Boy 700
Technical Description
SB700-11:EE
-
37
-
SMA Regelsysteme GmbH
Operation
Green LED on
Red LED off
Yellow LED off
The Sunny Boy has successfully completed self-testing electronics and the MSD and
starts feeding to the grid.
•
“MPP“-mode (default setting):
The Sunny Boy independently acquires the MPP voltage of the PV panel which
is internally defined as PV setpoint voltage. In MPP mode the maximum power
point P
AC
is set by changing the required PV voltage at the PV-panel.
•
“Constant Voltage“-mode
The voltage from the PV-modules can be set to a fixed value. This value (“U-
Konst”) can be manually defined by the operator and transmitted to the Sunny
Boy via the Sunny Boy Control or with the Sunny Data software. In the constant
voltage mode the Sunny Boy uses a strictly defined PV voltage setpoint.