Chapter 8
Diagnosing and Correcting FC-AL Loop Problems
8-3
FIGURE 8-1
contains a block diagram showing the two back-end drive loops in a
normal (no failures) configuration.
FIGURE 8-1
Backend Loop Configuration
Standard mirrored loop
configuration
Loop 1
Path 0
Interconnect card
Loop 2
Path 1
Interconnect card
Nonsplit loop
Normal:
Non-split configuration drives
u1d4-9 and u2d4-9 are logically
configured to loop 1 (path 0)
Interconnect card
Loop 1
Path 0
Alternate u2
Nonsplit loop
Normal:
Nonsplit configuration drives
u1d1-3 and u2d1-3 are logically
configured to loop 2 (path 1)
Interconnect card
Loop 2
Path 1
Loop
cables
Mirrored cache data also
transverses loop 2 (path 1)
as well
Master, u1
Summary of Contents for StorEdge T3+
Page 5: ...Regulatory Compliance Statements v ...
Page 14: ...xiv Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 36: ...1 6 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 70: ...3 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 86: ...4 16 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 154: ...8 30 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 164: ...9 10 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 188: ...10 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 222: ...D 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 228: ...F 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 240: ...Index 12 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...