Chapter 5
Disks and Drives
5-3
5.1.2
Checking the Hot Spare
1. Use the
vol list
command to check the location of the hot spare (standby)
drive.
2. Use the
vol stat
command to check the status of the hot spare drive.
All drives should show a status of
0
. See
TABLE 5-1
for definitions of drive status
codes.
:/:<41> vol list
volume capacity raid data standby
v0 125.2 GB 5 u1d1-8
u1d9
v1 125.2 GB 5 u2d1-8
u2d9
:/:<42> vol stat
v0 u1d1 u1d2 u1d3 u1d4 u1d5 u1d6 u1d7 u1d8 u1d9
mounted 0 0 0 0 0 0 0 0 0
v1 u2d1 u2d2 u2d3 u2d4 u2d5 u2d6 u2d7 u2d8 u2d9
mounted 0 0 0 0 0 0 0 0 0