Chapter 10
Hardware Reconfiguration
10-15
10.2
Disconnecting a Partner Group to Form
Single Controller Units
Caution –
Back up all data before beginning this procedure.
This section describes how to reconfigure a partner group to form two existing
single controller units.
This procedure includes the following sections:
■
Section 10.2.1, “Preparing the Arrays” on page 10-15
■
Section 10.2.2, “Establishing a New IP Address” on page 10-17
■
Section 10.2.3, “Establishing a Network Connection” on page 10-17
■
Section 10.2.4, “Defining and Mounting Volumes” on page 10-18
10.2.1
Preparing the Arrays
1. Back up all data on the partner group.
Caution –
Make sure you back up data before proceeding.
2. Ensure that the data path between the host and the partner group has been
quiesced.
There must not be any I/O activity.
3. Start a Telnet session with the master unit.
a. On the host, use the
telnet
command with the array name (or IP address) to
connect to the array.
b. Log in to the array by typing
root
and your password at the prompts.
The array prompt is displayed.
# telnet
array_name
Trying 129.150.47.101...
Connected to 129.150.47.101.
Escape character is ’^]’.
pSOSystem (129.150.47.101)
Summary of Contents for StorEdge T3+
Page 5: ...Regulatory Compliance Statements v ...
Page 14: ...xiv Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 36: ...1 6 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 70: ...3 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 86: ...4 16 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 154: ...8 30 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 164: ...9 10 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 188: ...10 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 222: ...D 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 228: ...F 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 240: ...Index 12 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...