Chapter 8
Diagnosing and Correcting FC-AL Loop Problems
8-27
13. Once the failed disk drive FRU has been identified, remove the suspect disk drive
from the configuration with the
vol disable
command.
May 26 19:20:04 CFGT[1]: N: u1ctr: Release A Loop: A Mask=<1>; B Mask=<1>
May 26 19:20:05 ISR1[1]: N: u1d4 SVD_PATH_FAILBACK: path_id = 1
May 26 19:20:05 ISR1[1]: N: u1d5 SVD_PATH_FAILBACK: path_id = 1
May 26 19:20:05 ISR1[1]: N: u1d6 SVD_PATH_FAILBACK: path_id = 1
May 26 19:20:05 ISR1[1]: N: u1d7 SVD_PATH_FAILBACK: path_id = 1
May 26 19:20:05 ISR1[1]: N: u1d8 SVD_PATH_FAILBACK: path_id = 1
May 26 19:20:05 ISR1[1]: N: u1d9 SVD_PATH_FAILBACK: path_id = 1
May 26 19:20:10 BELP[1]: N: u1l1 ONDG Loop Fault Diag Completed
May 26 19:20:10 ONDG[1]: N: FIND Initiated on u1l1
May 26 19:20:10 ONDG[1]: N: FIND Completed on u1l1
May 26 19:20:10 ONDG[1]: N: STATUS = PASS
May 26 19:20:10 ONDG[1]: N: u1 PASS
May 26 19:20:13 ONDG[1]: N: ONDG Completed
:/:<9> fru s u1d1-9
DISK STATUS STATE ROLE PORT1 PORT2 TEMP VOLUME
------ ------- ---------- ---------- --------- --------- ---- ------
u1d1 ready enabled data disk ready ready 44 v0
u1d2 ready enabled data disk ready ready 45 v0
u1d3 ready enabled data disk ready ready 37 v0
u1d4 ready enabled data disk ready ready 35 v0
u1d5 ready enabled data disk ready ready 38 v0
u1d6 ready enabled data disk ready ready 39 v0
u1d7 ready enabled data disk ready ready 40 v0
u1d8 ready enabled data disk ready ready 38 v0
u1d9 ready enabled data disk ready ready 37 v0
:/:<10> vol disable u1d9
:/:<11> fru s u1d1-9
DISK STATUS STATE ROLE PORT1 PORT2 TEMP VOLUME
------ ------- ---------- ---------- --------- --------- ---- ------
u1d1 ready enabled data disk ready ready 44 v0
u1d2 ready enabled data disk ready ready 45 v0
u1d3 ready enabled data disk ready ready 37 v0
u1d4 ready enabled data disk ready ready 35 v0
u1d5 ready enabled data disk ready ready 38 v0
u1d6 ready enabled data disk ready ready 39 v0
u1d7 ready enabled data disk ready ready 40 v0
u1d8 ready enabled data disk ready ready 39 v0
u1d9 fault disabled data disk ready ready - v0
Summary of Contents for StorEdge T3+
Page 5: ...Regulatory Compliance Statements v ...
Page 14: ...xiv Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 36: ...1 6 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 70: ...3 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 86: ...4 16 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 154: ...8 30 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 164: ...9 10 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 188: ...10 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 222: ...D 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 228: ...F 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 240: ...Index 12 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...