Sun StorEdge T3 and T3+ Array Field Service Manual • September 2001
2. Log in to the array by typing
root
and the supervisor password at the prompts.
5.1.1
Checking Drive Status Codes
●
Use the
vol stat
command to check drive status codes.
All drives should show a status of 0 under normal conditions.
The following table lists numeric drive status codes.
:/:<40> vol stat
v0 u1d1 u1d2 u1d3 u1d4 u1d5 u1d6 u1d7 u1d8 u1d9
mounted 0 0 0 0 0 0 0 0 0
v1 u2d1 u2d2 u2d3 u2d4 u2d5 u2d6 u2d7 u2d8 u2d9
mounted 0 0 0 0 0 0 0 0 0
TABLE 5-1
Drive Status Messages
Value
Description
0
Drive mounted
2
Drive present
3
Drive is spun up
4
Drive is disabled
5
Drive has been replaced
7
Invalid system area on drive
9
Drive not present
D
Drive is disabled and is being reconstructed
S
Drive substituted
Summary of Contents for StorEdge T3+
Page 5: ...Regulatory Compliance Statements v ...
Page 14: ...xiv Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 36: ...1 6 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 70: ...3 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 86: ...4 16 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 154: ...8 30 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 164: ...9 10 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 188: ...10 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 222: ...D 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 228: ...F 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 240: ...Index 12 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...