5-4
Sun StorEdge T3 and T3+ Array Field Service Manual • September 2001
5.1.3
Checking Data Parity
Caution –
It can take up to several hours for the parity check once the
vol verify
command is executed. Execution of this command might affect system performance,
depending on system activity and the verification rate selected.
●
Use the
vol verify
command to perform a parity check of the drives.
You can also use the
fix
and
rate
options:
Where:
■
fix
recalculates and rewrites the parity block if a mismatch is detected.
■
rate specifies the speed with 1= slowest and 8 = fastest.
Note –
The
vol
command is not re-entrant. Other
vol
commands cannot run on the
array or partner group until the
vol verify
operation has completed.
Note –
It is a good practice to run
vol verify
before recycling backup tapes to be
sure the image is correct before over-writing previous images.
:/:<7> vol verify
volume name
:/:<7> vol verify
volume name
[fix] [rate <1-8>]
Summary of Contents for StorEdge T3+
Page 5: ...Regulatory Compliance Statements v ...
Page 14: ...xiv Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 36: ...1 6 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 70: ...3 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 86: ...4 16 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 154: ...8 30 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 164: ...9 10 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 188: ...10 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 222: ...D 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 228: ...F 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 240: ...Index 12 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...