3-2
Sun StorEdge T3 and T3+ Array Field Service Manual • September 2001
■
LED = Light emitting diodes on the array.
■
CM = Component Manager.
■
CLI(E) = Command-line utilities run via ethernet connection as described in Sun
StorEdge T3 and T3+ Array Administrator’s Guide.
■
CLI(S) = Command-line utilities run via a serial connection as described in
Section 2.1, “Establishing a Serial Port Connection” on page 2-1.
■
OFDG = Off-line Drive Diagnostic utility as described in Section 8.3.8, “Using the
ofdg Diagnostic Utility” on page 8-16.
■
SNMP = Simple Network Monitoring Protocol as described in Sun StorEdge T3
and T3+ Array Administrator’s Guide.
■
SNMP(CA) = Simple Network Monitoring Protocol used with a customer-written
application as described in Sun StorEdge T3 and T3+ Array Administrator’s Guide.
System (admin domain)
configuration
CM, CLI(E), CLI(S)
System (admin domain)
monitoring
CM, CLI(E), CLI(S), SRS, SNMP(CA), syslog(CA)
Version level check
CM, CLI(E), CLI(S)
LUN configuration
CM, CLI(E), CLI(S)
FRU failure monitoring
LED, CM, CLI(E), CLI(S), SRS, SNMP(CA), syslog(CA)
Performance monitoring
CM, CLI(E), CLI(S), SNMP(CA), syslog(CA)
Firmware download
CLI(E)
Syslog access (mgmt host)
CLI(E), CLI(S), syslog(CA and StorTools(M) with 2nd copy of
StorTools running on management host with ethernet
connection to disk tray
Loop resiliency check
(manual)
OFDG, CLI(E), CLI(S)
Manual loop resiliency
check
OFDG, CLI(E), CLI(S)
Clear supervisor password
CLI(S)
Host data path diagnosis
StorTools(A) application
Statistics logging
syslog(CA) and StorTools(M) application with 2nd copy of
StorTools application running on management host with
Ethernet connection to disk tray
Service commands
CLI(E), CLI(S)
Mfg/repair commands
CLI(E), CLI(S)
TABLE 3-1
Diagnostic Functions and Tools (Continued)
Function
Tools That Can Be Used
Summary of Contents for StorEdge T3+
Page 5: ...Regulatory Compliance Statements v ...
Page 14: ...xiv Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 36: ...1 6 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 70: ...3 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 86: ...4 16 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 154: ...8 30 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 164: ...9 10 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 188: ...10 24 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 222: ...D 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 228: ...F 4 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...
Page 240: ...Index 12 Sun StorEdge T3 and T3 Array Field Service Manual September 2001 ...