5-1
764333-766
5.1 GENERAL
This section describes the types of STERIS 4085 General
Surgical Table malfunctions or situations that may occur
and indicates possible causes and suggested actions for
remedy. See
and
for a complete
listing and description of table situations.
If unable to correct the situation following the
Troubleshooting Guide and Alarm Chart or a situation
occurs that is not described in this section, please call
STERIS. A trained service technician will promptly place
your STERIS 4085 General Surgical Table in proper
working condition.
Calling For Service:
First, try to define the situation and
determine whether you can solve it yourself (see
and
). If you cannot solve the situation, call
STERIS and give the following information for the table:
serial number, model number, date of purchase.
NOTE: When troubleshooting, note the following:
1) Never permit unqualified persons to service this table.
2) When power supplies are operational, the table is
plugged into facility power and the Main Power
Switch is
ON
, the switch is illuminated green.
as follows:
• Situation - select the situation that best describes the
symptom the table is exhibiting.
• Cause - determine what has occurred to set off the
alarm or create this situation.
• Service Instructions - follow the list of conditions that
should be checked to isolate and correct the one
causing the problem. The instructions are listed in the
order in which they should be completed.
as follows:
• LCD Screen Wrench - when a situation occurs, the
control displays a wrench on the Hand Control LCD
(see
).
• Condition, Indication, Action - explanation of
situation and how to correct it.
IMPORTANT: A listing of the
S
AFETY
P
RECAUTIONS
to be observed when operating and servicing
this equipment can be found in
of this manual. Do not operate or service the
equipment until you have been trained on this information.
WARNING – PERSONAL INJURY AND/OR
EQUIPMENT DAMAGE HAZARD:
• Repairs and adjustments to this
equipment must be made only by
STERIS or STERIS-trained service
personnel. Maintenance performed by
unqualified personnel or installation of
unauthorized parts could cause
personal injury, result in improper
equipment performance, invalidate the
warranty or result in costly damage.
Contact STERIS regarding service
options.
• Regularly scheduled preventive
maintenance is required for safe and
reliable operation of this equipment.
Contact STERIS to schedule preventive
maintenance.
• Failure to perform periodic inspections
of the table could result in serious
personal injury or table damage.
WARNING – ELECTRIC SHOCK HAZARD:
Unplug surgical table from facility electrical
supply and remove battery fuse before
servicing. Always follow appropriate
electrical safety-related work practice
standards.
CAUTION – POSSIBLE EQUIPMENT
DAMAGE: When moving the table to or from
point of use, roll it carefully at moderate
speed and only over smooth floors.
Maximum floor clearance is 1/4" (6.4 mm).
Avoid elevator jambs or any obstructions
greater than 1/4" (6.4 mm). If necessary, lift
table over obstructions, onto trucks, etc. Lift
table evenly and only by the table base. If
transporting articles (including accessories)
on top of the table, ensure all articles are
properly secured to prevent falling off
tabletop. DO NOT use a forklift to move the
uncrated table.
Section 5: Troubleshooting
Summary of Contents for 4085
Page 1: ...MAINTENANCE MANUAL STERIS 4085 General Surgical Table 07 01 10 P764333 765 ...
Page 3: ...OPERATOR MANUAL STERIS 4085 General Surgical Table 04 15 09 P150832 639 ...
Page 131: ......
Page 172: ......
Page 173: ......
Page 174: ......
Page 175: ......
Page 176: ......
Page 177: ......