DocID024597 Rev 5
243/1830
RM0351
Reset and clock control (RCC)
278
6.4.14 APB1
peripheral
reset
register 2 (RCC_APB1RSTR2)
Address offset: 0x3C
Reset value: 0x00000 0000
Access: no wait state, word, half-word and byte access
Bit 3
TIM5RST
: TIM5 timer reset
Set and cleared by software.
0: No effect
1: Reset TIM5
Bit 2
TIM4RST
: TIM3 timer reset
Set and cleared by software.
0: No effect
1: Reset TIM3
Bit 1
TIM3RST
: TIM3 timer reset
Set and cleared by software.
0: No effect
1: Reset TIM3
Bit 0
TIM2RST
: TIM2 timer reset
Set and cleared by software.
0: No effect
1: Reset TIM2
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
Res.
LPTIM2
RST
Res.
Res.
SWP
MI1
RST
I2C4
RST
LP
UART1
RST
rw
rw
rw
rw
Bits 31:6 Reserved, must be kept at reset value.
Bit 5
LPTIM2RST
: Low-power timer 2 reset
Set and cleared by software.
0: No effect
1: Reset LPTIM2
Bits 4:3 Reserved, must be kept at reset value.