Embedded Flash memory (FLASH)
RM0351
104/1830
DocID024597 Rev 5
Programming errors
Several kind of errors can be detected. In case of error, the Flash operation (programming
or erasing) is aborted.
•
PROGERR
: Programming Error
In standard programming: PROGERR is set if the word to write is not previously erased
(except if the value to program is full zero).
•
SIZERR
: Size Programming Error
In standard programming or in fast programming: only double word can be
programmed and only 32-bit data can be written. SIZERR is set if a byte or an half-
word is written.
•
PGAERR
: Alignment Programming error
PGAERR is set if one of the following conditions occurs:
–
In standard programming: the first word to be programmed is not aligned with a
double word address, or the second word doesn’t belong to the same double word
address.
–
In fast programming: the data to program doesn’t belong to the same row than the
previous programmed double words, or the address to program is not greater than
the previous one.
•
PGSERR
: Programming Sequence Error
PGSERR is set if one of the following conditions occurs:
–
In the standard programming sequence or the fast programming sequence: a data
is written when PG and FSTPG are cleared.
–
In the standard programming sequence or the fast programming sequence:
MER1, MER2, and PER are not cleared when PG or FSTPG is set.
–
In the fast programming sequence: the Mass erase is not performed before setting
FSTPG bit.
–
In the mass erase sequence: PG, FSTPG, and PER are not cleared when MER1
or MER2 is set.
–
In the page erase sequence: PG, FSTPG, MER1 and MER2 are not cleared when
PER is set.
–
PGSERR is set also if PROGERR, SIZERR, PGAERR, MISSERR, FASTERR or
PGSERR is set due to a previous programming error.
•
WRPERR
: Write Protection Error
WRPERR is set if one of the following conditions occurs:
–
Attempt to program or erase in a write protected area (WRP) or in a PCROP area.
–
Attempt to perform a bank erase when one page or more is protected by WRP or
PCROP.
–
The debug features are connected or the boot is executed from SRAM or from
System flash when the read protection (RDP) is set to Level 1.
–
Attempt to modify the option bytes when the read protection (RDP) is set to
Level 2.
•
MISSERR
: Fast Programming Data Miss Error
In fast programming: all the data must be written successively. MISSERR is set if the
previous data programmation is finished and the next data to program is not written yet.
•
FASTERR
: Fast Programming Error