3-28 (E)
BVP-9500WS/9500WSP MM
A
3-3-9. RET Level Adjustment
Equipment:
Waveform monitor
Test point:
TEST OUT connector/side panel
Preparations
.
Extend the EN-141 board with the extension board (EX-762 board assembly or EX-464.)
.
Connect the waveform monitor to the TEST OUT connector/side panel.
.
Connect the optical/electrical cable between CA-950/950P and CCU-900/900P.
.
Inputs a 10 STEP signal to RET connector on the CCU-900/900P.
.
S801 (TEST OUT) /EN-141 board
→
RET
Adjustment procedure
1.
Adj. point:
1
RV802 (RET LEV) /EN-141 board
Specification:
A = 100
±
1 IRE [NTSC]
A = 700
±
5 mV [PAL]
Setting after adjustment
S801 (TEST OUT) /EN-141 board
→
CAM
3-3. Encoder System Adjustment
EN-141 BOARD (A SIDE)
E1
S600
S800
S801
S601
TP4
TP1
TP3
TP2
RV406
RV608
RV301
RV405
RV201
RV302
RV202
RV203
RV303
RV404
RV403
RV402
RV401
RV304
RV300
RV204
RV200
RV100
RV104
RV407
RV605
RV601
RV607
RV606
RV801
RV800
RV802
RV609
RV600
RV604
RV603
RV602
CN1
1
2
3
4
5
6
7
8
L
M
K
J
H
G
F
E
D
C
B
A
Summary of Contents for BVP-9500WS
Page 62: ......
Page 72: ......
Page 206: ......
Page 234: ......
Page 236: ......
Page 246: ......
Page 252: ......
Page 270: ......
Page 277: ......
Page 282: ......
Page 296: ......
Page 322: ......
Page 324: ......
Page 338: ......
Page 340: ......
Page 342: ......
Page 346: ......
Page 350: ......
Page 356: ......
Page 358: ......
Page 360: ......
Page 362: ......
Page 368: ......
Page 372: ......
Page 378: ......
Page 380: ......
Page 382: ......
Page 389: ......