3-6. Adjustment After Replacement of ND Filter
When any of the ND filters is replaced, the correction of white balance is required. Proceed as follows.
Equipment:
Waveform monitor
Test point:
TEST OUT connector/side panel
Object:
Full White Pattern
Preparations
.
Connect the waveform monitor the TEST OUT connector.
.
Shoot the fully occupied white area of the white pattern on the underscanned monitor frame.
.
Setting for MSU-700A
AUTO button (Iris control block)
→
ON (lit)
.
Iris of the lens: A = 600
±
20 mV
Adjustment Procedures
1.
STANDARD button/MSU-700A
→
ON (lit)
2.
FILTER CTRL button/MSU-700A
→
ON (lit)
3.
Select the ND 1 filter.
ND 1 button/MSU-700A
→
ON (lit)
4.
Adjust the white balance.
WHITE button/MSU-700A
→
ON (lit)
5.
After the white balance adjustment is complete, switch the filter from ND 1 to ND 2 and adjust the
white balance for the ND 2 filter.
6.
Switch the filter from ND2 to ND3 to ND4 to ND5, and adjust the white balance for each.
OHB File Store
1.
MSU menu operation:
.
FILE button
→
ON (lit)
.
Touch panel operation
[OHB|File]
→
[OHB|Store]
→
[Store]
2.
When the store operation is complete, the message “OHB File Stored” is displayed.
3-6. Adjustment After Replacement of ND Filter
Summary of Contents for BVP-9500WS
Page 62: ......
Page 72: ......
Page 206: ......
Page 234: ......
Page 236: ......
Page 246: ......
Page 252: ......
Page 270: ......
Page 277: ......
Page 282: ......
Page 296: ......
Page 322: ......
Page 324: ......
Page 338: ......
Page 340: ......
Page 342: ......
Page 346: ......
Page 350: ......
Page 356: ......
Page 358: ......
Page 360: ......
Page 362: ......
Page 368: ......
Page 372: ......
Page 378: ......
Page 380: ......
Page 382: ......
Page 389: ......