3-23 (E)
BVP-9500WS/9500WSP MM
A
A
[NTSC]
[PAL]
3-3-5. Y Level Adjustment
Equipment:
Oscilloscope
Preparations
.
Extend the EN-141 board with the extension board (EX-762 board assembly or EX-464.)
.
Disconnect the triax cable or optical fiber cable from CCU.
.
Supply power from the AC adaptor (AC-550/550CE).
.
OUTPUT switch/side panel
→
BARS
Adjustment procedure
1.
Test point:
TP4/EN-141 board
GND:
E1/EN-141 board
Adj. point:
1
RV407 (Y BL) /EN-141 board
Specification:
A = 0
±
5 mV
3-3. Encoder System Adjustment